Hangzhou PRI-SAFETY Fire Technology Co., Ltd. is known as one of the most professional manufacturers and suppliers of various safety products in China. If the high quality hfc-227ea total flooding system meets your requirement, welcome to buy quality equipment made in China here from our factory. Our factory will offer you one stop service and one year warranty.



Product Description
HFC-227ea/FM-200, is a clean gaseous fire suppression agent commonly used in total flooding fire protection systems. The FM200 system is designed to extinguish fires by rapidly reducing the oxygen concentration within a protected space, thereby suppressing the combustion process. This type of fire suppression system is typically employed in areas where water-based systems might be ineffective or where the use of water could cause damage to sensitive equipment or valuable assets.
Product Specifications
| No. | Specificaitons | Technical Parameter | |
| 1 | Filling Pressure | 4.2Mpa | 5.6Mpa |
| 2 | Spray Time | 10S | |
| 3 | Cylinder Material | Stainless Steel SUS304 | |
| 4 | Cylinder Head Size | G1" / G2" | |
| 5 | Filling density | ≤950kg/m3 | ≤1080kg/m3 |
| 6 | Max working pressure | 5.3Mpa | 8.0Mpa |
| 7 | Cylinder Capacity | 70L, 90L, 120L, 150L, 180L, 250L, 345L | |
| 8 | Condition of reserving room for container | Temperature: -10~50ºC, Relative humidity: ≤97% |
|
| 9 | Nitrogen Pressure of Driving Device | 6.0±1.0Mpa(20ºC) | |
| 10 | Valve Material | Stainless Steel SUS304 | |
| 11 | Power | DC24V/1.6A | |
| 12 | Scale of Protective region for one zone | Area:max single-zone is 800m² volume:max single-zone is 3600 | |
Key Features
Clean Agent:
HFC-227ea/FM-200 is a clean gaseous agent, meaning it leaves no residue after discharge. This is particularly important in environments with sensitive electronic equipment, data centers, museums, and other areas where the residue from traditional firefighting agents (like water or foam) could cause damage.
Rapid Suppression:
HFC-227ea/FM-200 is designed to rapidly suppress fires by reducing the oxygen concentration in the protected space. This helps to control and extinguish the fire quickly, minimizing damage to property and reducing downtime.
Effective on Class A, B, and C Fires: FK-5112 Novec 1230 is effective on a wide range of fires, including those involving ordinary combustibles (Class A), flammable liquids (Class B), and electrical fires (Class C). It works by interrupting the combustion process without causing harm to electronic equipment.
Low Ozone Depletion Potential (ODP):
HFC-227ea/FM-200 has a low ODP, meaning it has a minimal impact on the ozone layer compared to some other halogenated fire suppression agents.
Short Atmospheric Lifetime:
HFC-227ea/FM-200 has a relatively short atmospheric lifetime, which contributes to its environmental acceptability. It has a Global Warming Potential (GWP) that is much lower than certain other chemical fire suppression agents.
Safe for Occupied Spaces:
HFC-227ea/FM-200 is considered safe for use in occupied spaces when applied in accordance with design and safety standards. It does not produce toxic by-products in the concentrations used for fire suppression.
Colorless and Odorless:
HFC-227ea/FM-200 is colorless and odorless, making it imperceptible to humans during discharge. This is beneficial in situations where occupants need to evacuate or emergency responders need to work without hindrance.
Precision Delivery:
The system is designed for precision delivery of the agent through a network of pipes and strategically placed nozzles. This ensures even distribution and effective coverage of the protected area.
Compatibility with Electronics:
FM200 is non-conductive and safe for use in areas with sensitive electronic equipment. It can be an ideal choice for protecting server rooms, data centers, control rooms, and other spaces with valuable electronic assets.
Compliance with Standards:
HFC-227ea/FM-200 systems are designed and installed in compliance with industry standards and regulations. This includes adherence to guidelines provided by organizations like the National Fire Protection Association (NFPA) and local authorities.
Activation Methods:
Solenoid Head Activation Model:

A solenoid valve-activated HFC-227ea/FM-200 fire system is a type of fire suppression system that uses a solenoid valve as a key component in the activation process. The solenoid valve is an electromechanical device that controls the flow of the HFC-227ea/FM-200 fire suppression agent from the storage container to the distribution pipes and nozzles in the protected space.
Solenoid Valve: The solenoid valve is an electrically operated valve that controls the release of the HFC-227ea/FM-200 agent. It is typically located on the piping that connects the storage container or cylinders to the distribution network. When an alarm signal is received or manual activation is initiated, the solenoid valve opens to allow the pressurized HFC-227ea/FM-200 to flow into the distribution system.

Pilot Bottle Activation Model:

A pilot bottle-activated HFC-227ea/FM-200 fire system is a type of fire suppression system that relies on a pilot cylinder or bottle to initiate the release of the HFC-227ea/FM-200 extinguishing agent. This system is commonly used in applications where a fast and precise response is required for fire protection. The pilot bottle serves as a smaller, independent container of the extinguishing agent that is connected to the main storage container.
Here's how a pilot bottle-activated HFC-227ea/FM-200 fire system typically works:
Pilot Bottle: The pilot bottle contains a smaller quantity of HFC-227ea/FM-200 and is pressurized. It is connected to a network of pipes that are also connected to the main storage container.
Pilot Line: A pilot valve is associated with the pilot bottle. This valve is designed to open when a specific condition is met, such as an increase in temperature or the activation of a smoke or heat detector. The pilot valve is usually a heat-sensitive device that responds to the elevated temperatures associated with a fire.
Pilot Line: The pilot bottle is connected to a pilot line that runs through the protected area. This line is typically smaller than the main distribution piping and is designed to actuate the main solenoid valve when the pilot valve opens.
Main Solenoid Valve: Similar to solenoid valve-activated systems, a main solenoid valve is used to control the flow of HFC-227ea/FM-200 from the main storage container to the distribution network. When the pilot valve opens due to a fire condition, it triggers the main solenoid valve to open, releasing the HFC-227ea/FM-200 into the protected space.
Accessory Parameters:
HFC-227ea/FM-200 Cylinder Specification---4.2MPa:
(Just Listed some bottle specifications for reference)

HFC-227ea/FM-200 Cylinder Specification---5.6MPa:
(Just Listed some bottle specifications for reference)



Specifications for Head Valve of HFC-227ea/FM-200 Fire System
(High Level Model)


HFC-227ea/FM-200 Nozzle for Pipework Type


Control Panel Components:
The control panel for an FM200 total flooding system is a critical component that monitors, controls,
and coordinates the various elements of the fire suppression system.
The components are as followings:

Our Workshop: