Hangzhou PRI-SAFETY Fire Technology Co., Ltd. is known as one of the most professional manufacturers and suppliers of various safety products in China. If the pri-safety fk5112 rack mounted automatic fire suppression unit meets your requirement, welcome to buy quality equipment made in China here from our factory. Our factory will offer you one stop service and one year warranty.

 

PRI-SAFETY FK5112 Rack Mounted Automatic Fire Suppression Unit

 

rack fire system 4

 

 

 

Products Description

 

 

 

Our Server Rack Fire Suppression System is an integrated, self-contained solution engineered to provide rapid fire detection and effective extinguishing for enclosed 19-inch IT server racks and network cabinets. By utilizing advanced clean agent fire suppression technology with a non-conductive, residue-free extinguishing agent such as FK5112, it ensures that your sensitive and costly electronic equipment is protected from fire without sustaining damage from the suppression process itself . This all-in-one system is designed for easy installation in new or existing facilities, occupying minimal space-often as little as 1U of rack height-making it the ideal choice for safeguarding critical IT infrastructure.

 

Automatic Control Mode

PRI-SAFETY Rack Fire System's Fire Detection consists of 4 detectors ---- 2 of smoke detectors , 2 of sensor cables , 

When fire breaks out inside Server Rack , PRI-SAFETY Rack Fire System would detect it and put out fire effectively  in 10 seconds. 

 

1. When any 1 detector detects fire , the red Alarm light is activated.


2. When any 2 detectors both detect fire , the Light/Siren light is activated, and the solenoid valve is activated to discharge FK5112 Agent to extinguish fire quickly. During the releasing period, the Light/Siren light continues to sound and light alarm. The Gas Release light is also activated.


3. Activation Mechanism : 2 smoke sensors, 2 detection cables, any 2 combinations can activate the solenoid valve:
(1) 2 smoke sensors--activate the solenoid valve to spray
(2) 2 detection lines--activate the solenoid valve to spray 
(3) 1 smoke sensor + 1 detection line---activate the solenoid valve to spray

 

Products Advantage

 

 

 

• Localized Protection:

Protects only high-risk areas in the rack, reducing downtime and damage in unaffected spaces, and offering targeted fire suppression exactly where needed without disturbing other areas.

 

• Quick and Efficient Suppression:

Rapid fire detection and suppression contain fires within seconds, minimizing damage to equipment, data loss, and service interruptions.


• Minimizes Downtime:

Recovery time is drastically reduced with FK5112, the non-corrosive and non- residue clean agent. Once the fire is suppressed, your equipment can be restored quickly without the need for extensive cleaning or replacement of damaged hardware.

 

• Easy Installation and Integration:

Compact design fits standard racks, requiring minimal setup and integrates smoothly with fire alarm systems, enhancing safety with simple installation.

 

• Safe for Personnel:

Clean agents are non-toxic and safe for use in occupied spaces. This means that personnel working in data centers or near the equipment will not be harmed if the system is activated.

 

• Cost-Effective:

Affordable and easy to maintain, providing essential, targeted protection for high-value assets without the cost of full-room suppression systems

rack fire system 5
 

Specification

 

 
Technical Parameters
Manufacturer Brand PRI-SAFETY
Model PRI-R-01
Cabinet Protection IP 30
Extinguishing Agent FK-5112
Operating Position Horizontal
Detector Detection cable & Smoke detector
Operation Tempertature Range -20°C~+60°C
Main Input Powder 110~240v,50/60 HZ
Backup Battery Rechargable Sealed Lead-Acid Battery
Cabinet Dimension L508mm/W425mm/H88mm(2U)
Weight without Agent 10.4kg
Agent Weight 2kg
Discharge Time 50s
Working Pressure 14 Bar
 

Components List

 

     rack fire system 6

1. Fire Detection System: The unit incorporates highly sensitive smoke and heat detectors to identify the earliest signs of fire or overheating. These detectors continuously monitor the internal environment of the rack, ensuring that any anomalies are caught before a fire can develop.

 

2. Clean Fire Suppression Agent: The system typically uses a clean agent-- FK5112, which is safe for use around sensitive electronics. These agents suppress the fire by rapidly cooling the flames and interrupting the combustion process without leaving any residue. They are non-conductive and ensure no damage to hardware, keeping your servers and equipment safe and operational.

 

3. Automatic Discharge Mechanism: Upon detection of smoke or a temperature rise above a critical threshold, the system automatically releases the suppression agent directly into the rack space. This fast, targeted discharge ensures that the fire is quickly suppressed before it can cause extensive damage to equipment.

 

4. Control and Alarm Panel: The unit is equipped with an easy-to-use control panel that integrates with your building's existing fire detection system. Alarms are triggered upon detection, notifying personnel or the fire response team to take action. Additionally, it can be configured for remote monitoring to provide constant surveillance over critical infrastructure.

 

5. Compact Design for Server Racks: The system is designed to fit within the standard 19-inch rack size, requiring minimal space. It is mounted either at the top or side of the rack, depending on the configuration, ensuring it doesn't interfere with equipment placement while still providing localized protection.

 

6. Manual Activation Option: In addition to the automatic feature, the unit typically includes a manual activation option, allowing personnel to engage the system if a fire risk is detected before the system automatically triggers.

 

 

Application

 

• Data Centers: Protecting server racks and critical IT infrastructure from fire damage.
• Telecommunications Racks: Ensuring continued operation of telecom systems by preventing fire-induced outages.
• Laboratories and Medical Equipment: Safeguarding sensitive equipment in labs, hospitals, and other specialized environments.
• Archival Storage: Protecting digital archives and critical data storage systems.

Rack Fire System 4

 

 

 

Company Profile

 

product-900-600

PRI-SAFETY FIRE TECHNOLOGY is established in 2005, is focused on Automatic Fire Suppression Systems and Fire Equipment R&D, Design and Manufacture.

 

The Main Products are On/Off Road Vehicles & Machines Automatic Fire Suppression system, HFC-227ea & FK-5112 Clean gas Fire Suppression systems, CAFS(Mobile Compressed Air Foam System), Water Mist Fire System, Foam Mist Fire System, Co2 Fire System, etc.

 

The Products and Fire Systems are used in Mining Industry, Forest Industry, Agriculture, Petrochemical, Transportation, Electricity Power, Industry, Construction and other fields.

 

PRI-SAFETY Has Professional Technology Team, Have Ability Supply Design, Solution, and Customization, For Special Project Requirement, and Technology Training & Instruction After Sales.

PRI-SAFETY Has the Certificates, ISO9001:2015, TUV CE0036, ECE R107, CCC, and So On. The Products Meet the International Standard of EN, NFPA, CNAS, ECE, etc.

 

 

 

Hot Tags: PRI-SAFETY FK5112 Rack Mounted Automatic Fire Suppression Unit, China, manufacturers, suppliers, factory, made in China, Fire And Safety Signs