HFC-227ea Gas Total Flooding Fire System

HFC-227ea Gas Total Flooding Fire System

The Novec1230 / FK-5112 total flooding fire suppression system offers fast and residue-free extinguishment of fires in critical environments. Utilizing a clean agent that evaporates quickly upon discharge, it effectively extinguishes fires without leaving...
Send Inquiry
Chat Now
Description
Technical Parameters

Hangzhou PRI-SAFETY Fire Technology Co., Ltd. is known as one of the most professional manufacturers and suppliers of various safety products in China. If the hfc-227ea gas total flooding fire system meets your requirement, welcome to buy quality equipment made in China here from our factory. Our factory will offer you one stop service and one year warranty.

 

 

DSC6107

 

1
Product description

 

When the control mode selection key on the automatic fire alarm and fire extinguishing controller is set to the "auto" position, the fire extinguishing system is under automatic control. When a fire occurs in the protection area, the temperature and smoke detectors will send out a fire signal through the automatic fire alarm and extinguishing control After the logic analysis of the device, it sends out a combined sound and light alarm signal, and sends out a linkage command at the same time to close the linkage device.
After a delay, a fire extinguishing command is issued, the starting valve is opened to release the starting gas, and the starting gas is opened through the control gas pipeline valves and container valves release the fire extinguishing agent and implement fire extinguishing.
 

 

Advantages: Automatic HFC-227ea/FM-200 Total Flooding Fire System, HFC-227ea/FM-200 clean gas automatic fire suppression systems

 

Very swift fire suppression. Reach extinguishing level ≤10s. Safe to people. People is safe when exposed at the HFC-227ea/FM-200 gas discharge level. Low extinguishing concentration. Nearly no obscure to vision in person evacuation. Easy to clean. No residue left, and minimize damage to sensitive equipment. Environment friendly. Zero ozone depletion potential and zero global warming potential. Simple installation, with small storage space.

 

2
Specifications

 

Specification of Pipe Network FM200 Fire Suppression Systems Technical Parameter of Pipe Network HFC-227ea/FM-200 Fire Suppression Systems
Filling pressure 4.2Mpa
Scale of Protective region for one zone Area:max single-zone is 800m² volume:max single-zone is 3600m³
Spraying time ≤10s
Filling density ≤950kg/m3
Power DC24V/1.6A
Nitrogen Pressure of Driving Device 6.0±1.0Mpa(20℃)
Condition of reserving room for container temperature: -10~50℃, relative humidity: ≤97%
Max working pressure 5.3Mpa
Min working pressure 4.2Mpa
Capacity 90L, 120L, 150L, 180L
   

 DSC5844DSC5815

 

3
Products Details

 

1. Storage cylinder: Cylinder, container valve (with pilot valve, pressure indicator), dip tube, etc.
2. High pressure hose: Connect cylinder valve and liquid checkvalve
3. Discharge Nozzle: Fitted at the end of pipe network to discharge fire suppressing agent
4. Control System: Control panel, smoke and heat detector, fire alarm, discharge indicator light, etc

1

Novec

Novec Nozzles

4
Working Principle

HFC-227ea FM200 fire system devices are generally used in conjunction with fire detectors, fire alarm fire extinguishing controllers, emergency start/stop buttons, sound and light alarms, deflation indicators and other fire fighting equipment. When a fire occurs in the protection area, the temperature and smoke detectors will send out a fire signal.

 

After the logic analysis of the automatic fire alarm and extinguishing controller, it will send out a sound and light composite alarm signal, and at the same time send out a linkage command to turn off the linkage equipment.

 

After a delay time, a fire extinguishing command is issued, the solenoid valve driver is opened, the container valve is opened, the fire extinguishing agent is released, and the fire is extinguished; if the duty officer discovers a fire, he can press the emergency start button outside the protective area door to implement the fire extinguishing operation ; There is also a manual button on the solenoid valve driver, and mechanical emergency manual operation can also be used to extinguish fire in an emergency.

 

I. Single Bottle With Pilot Bottle or With Solenoid Valve

FM200-02 1000
FM200-01 1000

II. Multiple Bottle With Pilot Bottle or With Solenoid Valve

FM200-04 1000
FM200-03 1000

III. Multi-Room Distribution System with Pilot Bottle

FM200-07 1000
FM200-08 1000

 

5
Our Workshop

 

1. Very swift fire suppression. Reach extinguishing level ≤10s.


2. Safe to people. People is safe when exposed at the FM200 gas discharge level.


3. Low extinguishing concentration. Nearly no obscure to vision in person evacuation.


4. Easy to clean. No residue left, and minimize damage to sensitive equipment.


5. Environment friendly. Zero ozone depletion potential and zero global warming potential.


6. Simple installation, with small storage space.

FM200 Workshop

 

6
Packing & Shipping

Packaging heavy goods like the FM200 total flooding fire system requires careful planning to ensure safe transportation and delivery. Here are some guidelines for packaging such systems:

 

1. Use Sturdy Pallets
Material: Opt for heavy-duty wooden or metal pallets that can support the weight of the system.
Size: Ensure the pallet is appropriately sized to prevent any overhang, which could lead to instability.


2. Secure the System
Strapping: Use high-strength steel or polyester strapping to tightly secure the FM200 system to the pallet.
Corner Protectors: Apply corner protectors to distribute the pressure of the strapping and protect the system from damage.

 

3. Cushioning and Protection
Padding: Use foam padding, bubble wrap, or industrial-grade cushioning materials to protect the system from shocks and vibrations.

Packing