High Pressure Engineered FM200 HFC-227ea Total Flooding Fire Systems

High Pressure Engineered FM200 HFC-227ea Total Flooding Fire Systems

Pipe Network FM200 Total Flooding Fire Suppression System 1. Product Description: FM-200 is an odorless, colorless, liquefied compressed gas. It is stored as a liquid and dispensed into the hazard as a colorless, electrically non-conductive vapor that is clear and does not obscure vision. It...
Send Inquiry
Chat Now
Description
Technical Parameters

Hangzhou PRI-SAFETY Fire Technology Co., Ltd. is known as one of the most professional manufacturers and suppliers of various safety products in China. If the high pressure engineered fm200 hfc-227ea total flooding fire systems meets your requirement, welcome to buy quality equipment made in China here from our factory. Our factory will offer you one stop service and one year warranty.

 

FM 200 HFC-227ea Total Flooding Fire Suppression Systems

1. Product Description:

FM 200 HFC-227eais an odorless, colorless, liquefied compressed gas. It is stored as a liquid and dispensed into the hazard as a colorless, electrically non-conductive vapor that is clear and does not obscure vision. It leaves no residue and has acceptable toxicity for use in occupied spaces at design concentration. FM 200 HFC-227ea extinguishes a fire by a combination of chemical and physical mechanisms.
FM 200 HFC-227ea provides excellent fire protection in a wide range of applications from sensitive electrical equipment to industrial applications using flammable liquids. FM 200 HFC-227ea agent is used in total flooding fire suppression systems.
FM-200 does not work by displacing oxygen and is safe for use in occupied spaces without fear of oxygen deprivation.

+--4

2. Components of Pipe Network FM 200 HFC-227ea Fire Suppression Systems

1. Storage cylinder: Cylinder, container valve (with pilot valve, pressure indicator), dip tube, etc.

2. Liquid check valve: Assure one way flow of fire suppression agent, to prevent backflow.

3. High pressure hose: Connect cylinder valve and liquid check valve .

4. Safety valve: Fitted on the manifold to relieve higher pressure.

5. Selection valve: Guide fire suppression agent into different distribution pipe network.

6. Starting gas bottle: Bottle, container valve, electromagnetic drive device, pressure gauge.
7. Gas check valve: Assure one way flow of starting gas, to prevent backflow.

8. Low leakage high sealing valve: For accumulated starting gas release so to avoid malfunction of system.

9. Discharge Nozzle: Fitted at the end of pipe network to discharge fire suppressing agent.

10. Control System: Control panel, smoke and heat detector, fire alarm, discharge indicator light, etc.Pri-Safety 90kg Pipe Network FM200 Fire Suppression System From Manufacturer

3. Advantage:

* Very swift fire suppression. Reach extinguishing level ≤10s.


* Safe to people. People is safe when exposed at the FM 200 HFC-227ea gas discharge level.

* Low extinguishing concentration. Nearly no obscure to vision in person evacuation.

* Easy to clean. No residue left, and minimize damage to sensitive equipment.

* Environment friendly. Zero ozone depletion potential and zero global warming potential.

* Simple installation, with small storage space.

SEO

4. Product Parameters

ItemModelVolume x Qty

Capacity

(FM 200 HFC-227ea)

Working Pressure (20ºC)Max Working Pressure (50ºC)Activate voltage/ currentOperating Temperature Range
1GMQ4.2/90N-PRI90X1≤100.8kg4.2Mpa5.6MpaDC24 V/1.2A0ºC-50ºC
2GMQ4.2/120N-PRI120X1≤134.4kg4.2Mpa5.6MpaDC24 V/1.2A0ºC-50ºC
3GMQ4.2/150N-PRI150X1≤168kg4.2Mpa5.6MpaDC24 V/1.2A0ºC-50ºC
4GMQ4.2/180N-PRI180X1≤201.6kg4.2Mpa5.6MpaDC24 V/1.2A0ºC-50ºC

5. Working Principle:

When the control mode selection key on the automatic fire alarm and fire extinguishing controller is set to the "auto"position, the fire extinguishing system is under automatic control. When a fire occurs in the protection area, the temperature and smoke detectors will send out a fire signal through the automatic fire alarm and extinguishing control After the logic analysis of the device, it sends out a combined sound and light alarm signal, and sends out a linkage command at the same time to close the linkage device. After a delay, a fire extinguishing command is issued, the starting valve is opened to release the starting gas, and the starting gas is opened through the control gas pipeline valves and container valves release the fire extinguishing agent and implement fire extinguishing.

FM200 Pipe work Principle

6. Product Applications:


MODEL ONE WITH ZONE VALVE


Pri-Safety 90kg Pipe Network FM200 Fire Suppression System From Manufacturer

MODEL TWO WITHOUT ZONE VALVE


Pri-Safety 90kg Pipe Network FM200 Fire Suppression System From Manufacturer


We also have Cabinet Type FM 200 HFC-227ea total Flooding Fire System, FK-5-1-12/ HFC-227ea fire extinguishing system Cabinet Type FK-5-1-12/ HFC-227ea Fire Extinguisher

FM200 CABINET

FM200 Cabinet-01

-01

• Bank vaults
• Libraries
• Book stores
• Electronic data processing
• Telephone exchanges
• Communication centers • Transformer and switch room
• Control rooms
• Test laboratories
• Flammable liquid storage

SEO

7. Our workshop

FM200 Workshop-SEO

8. Contact ways

--SEO