To meet worldwide project requirements, our company offers six fully engineered fire-suppression configurations, covering all combinations of:
System Type: Pipe Network / Cabinet Type
Cylinder Material: HP345(GB/T6653) Steel / Stainless Steel
Clean Agent: FM200 / Novec 1230
All six models are available, and we provide one-stop service including project design, OEM manufacturing, onsite installation assistance, and online/offline technical training.
⭐ This product page refers to the Link 3 ➡ Pipe Network + Stainless Steel Cylinder (304 or 316) + FM200 (HFC 227ea) Fire Agent
Products Description
FM200 Fire Suppression System
Stainless Steel Cylinder Pipe Newwork total flooding systems for single-room or multi-rooms.
What Is an FM200 Fire Suppression System
An FM200 fire suppression system is a total flooding gas fire extinguishing system that releases HFC-227ea clean agent into an enclosed space to suppress fire rapidly and effectively.
The agent works by absorbing heat and interrupting the combustion process, without damaging sensitive equipment or leaving any residue.
FM200 systems are especially suitable for critical facilities where water or powder systems are not acceptable.
How the FM200 Fire Suppression System Works?
Fire Detection
Smoke and heat detectors identify fire at an early stage.
Control and Alarm
The gas fire extinguishing control panel activates audible and visual alarms and initiates the release sequence.
Agent Discharge
The solenoid or pneumatic actuator opens the cylinder valve, releasing FM200 gas into the protected area.
Total Flooding Fire Suppression
FM200 gas reaches extinguishing concentration within seconds, suppressing fire quickly and effectively.
Clean and Safe Protection
The system leaves no residue, causes no corrosion, and allows rapid recovery after discharge.

FM200 System Main Components
Some accessories are available in multiple widths.

We also offer fire alarm fire systems together.

Products Specification
1. FM200 Stainless Steel Cylinder Fire Suppression System (Pipe Network Type) Specification
| Item | Specification |
| System Type | Pipe Network Total Flooding FM200 Fire Suppression System |
| Fire Suppression Agent | FM200 (HFC-227ea) |
| Cylinder Material | SUS306 or 316L |
| Cylinder Capacity Options | 16L / 32L / 40L / 52L / 70L / 82.5L / 90L / 100L / 120L / 140L / 150L / 180L / 250L / 300L / 345L / 450L / 500L |
| Working Pressure | 4.2 MPa (standard) / 5.6 MPa / 8.0 MPa (optional) |
| Discharge Time | ≤ 10 seconds |
| Design Concentration | 7.0% – 9.0% (depending on application) |
| Operating Temperature | -10°C to +50°C |
| System Activation | Automatic / Manual / Emergency Mechanical |
| Nozzle Type | 180°or 360° |
| Protected Area | Single zone or multi-zone protection |
| System Service Life | ≥ 20 years (with proper maintenance) |
2. Advantages of FM200 Fire Suppression System
* Clean agent with zero residue – no damage to electronics
* Fast fire extinguishing – minimizes asset loss and downtime
* Safe for occupied spaces – suitable for personnel areas
* Flexible pipe network design – ideal for complex layouts
* Scalable system configuration – supports large projects
* High reliability – certified cylinders and valves
* Long service life – industrial-grade components
*Superior corrosion resistance – with stainless steel cylinders, suitable for humid and harsh environments
Products Project Shows
Products Applications
Idea for, but not limited to:
* Data centers and IDC facilities
* Server rooms and UPS rooms
* Electrical switchgear rooms
* Power control rooms
* Telecommunication facilities
* Industrial automation systems
* Petrochemical control rooms
* Archives, libraries and laboratories
Packaging & Delivery
Cylinders secured with protective frames
Valves and accessories packed individually
Export-grade wooden pallet
Palletized packaging available for bulk shipments
Suitable for sea, air and land transportation
FQA
FM200 Fire Suppression System – Frequently Asked Questions (FAQ)
Q1: What is an FM200 fire suppression system?
An FM200 fire suppression system is a total flooding clean agent fire extinguishing system that uses HFC-227ea gas to suppress fire quickly and effectively.
It extinguishes fire by absorbing heat and interrupting the chemical reaction of combustion, without leaving residue or damaging sensitive equipment.
Q2: What is FM200 made of?
FM200 uses HFC-227ea (Heptafluoropropane) as the extinguishing agent.
It is a colorless, electrically non-conductive clean agent with zero ozone depletion potential (ODP = 0) and is widely accepted as a replacement for Halon 1301.
Q3: Is FM200 safe for people?
Yes. When designed and installed according to NFPA 2001 standards, FM200 systems are safe for occupied spaces.
The normal design concentration is within the NOAEL (No Observed Adverse Effect Level), making it suitable for data centers, control rooms and other manned areas.
Q4: What is the difference between pipe network FM200 and cabinet FM200 systems?
Pipe network FM200 system:
Designed for large or complex spaces, distributing gas through pipelines and nozzles. It supports multi-room protection using selector valves.
Cabinet FM200 system:
Compact and self-contained, suitable for small rooms or single protected areas.
Both systems use the same FM200 agent; the selection depends on room size and layout.
Q5: How fast does an FM200 system extinguish fire?
FM200 systems typically discharge the agent and reach extinguishing concentration within 10 seconds, allowing rapid fire suppression and minimizing damage to assets and downtime.
Q6: Does FM200 leave any residue after discharge?
No. FM200 is a clean agent and leaves no residue, no moisture and no corrosive by-products.
After discharge, the protected area can be returned to operation quickly without cleanup.
Q7: Where are FM200 fire suppression systems commonly used?
FM200 systems are widely used in:
Data centers and server rooms
Electrical switchgear rooms
UPS and battery rooms
Telecommunication facilities
Industrial control rooms
Petrochemical and power plants
Archives, libraries and laboratories
Q8: Can one FM200 system protect multiple rooms?
Yes. A pipe network FM200 system with selector valves can protect multiple rooms using a single cylinder group.
The system releases FM200 only into the room where fire is detected, improving efficiency and reducing cost.
Q9: How is the required FM200 gas quantity calculated?
The required FM200 agent quantity is calculated based on:
Room volume
Design concentration
Minimum temperature
Leakage and enclosure integrity
Our engineering team provides professional gas quantity calculation and room integrity analysis as part of our one-stop service.
Q10: What working pressure options are available for FM200 cylinders?
We offer FM200 cylinders with:
4.2MPa working pressure
5.6MPa working pressure
8.0MPa working pressure
Different pressure options allow flexible system design for various room sizes and piping distances.
Q11: What certifications do your FM200 systems have?
Our FM200 fire suppression systems are manufactured under ISO9001 quality management system and are CCC certified.
Key components comply with CE and EN standards, and the FM200 agent is UL listed.
Q12: Do you provide system design and installation support?
Yes. We provide a complete one-stop service, including:
System design and engineering
Customized manufacturing
Installation guidance or on-site support
System commissioning
Technical training (online and on-site)
Q13: Can you provide OEM or customized FM200 systems?
Yes. We support OEM / ODM services, including:
Customized cylinder sizes
Private labeling
Special pressure requirements
Project-specific system configurations
Q14: What maintenance does an FM200 system require?
FM200 systems require:
Periodic visual inspection
Pressure gauge checks
Detection and control panel testing
Annual system inspection according to local standards
We provide maintenance training to ensure long-term reliability.
Q15: How long is the service life of an FM200 system?
With proper installation and maintenance, FM200 systems typically have a service life of 15–20 years.
Cylinders, valves and accessories are designed for long-term industrial use.
Q16: How long does it take to deliver an FM200 system?
Standard production lead time is 15-20 days, depending on system configuration and order quantity.
Large or customized projects may require additional time.
Q17: Can you provide drawings and technical documents before ordering?
Yes. We can provide:
System layout drawings
Piping and nozzle distribution drawings
Wiring diagrams
Technical datasheets
Q18: How can I choose the right FM200 system for my project?
Simply contact us with:
Room dimensions
Application type
Number of rooms
Local standards
Our engineers will provide a customized FM200 fire suppression solution tailored to your project.
About Us
Why Choose Our PRI-SAFETY FM200 Fire Suppression System
One-Stop Fire Protection Solution from Design to Training
Our FM200 Fire Suppression System is a proven total flooding clean agent solution designed for fast and reliable fire protection in large and complex enclosed spaces.
We provide a complete one-stop service, covering project design, customized manufacturing, installation support and technical training, ensuring smooth delivery from concept to operation.
This system uses HFC-227ea, a clean, residue-free and electrically non-conductive fire extinguishing agent, widely applied in data centers, electrical rooms and industrial control environments.
One-Stop Service Capability
We are not only a manufacturer, but a full-solution provider of FM200 fire suppression systems.
* Project Design & Engineering
System design according to NFPA 2001, ISO, EN and local standards
FM200 gas quantity calculation and room integrity analysis
Pipe network layout and nozzle distribution drawings
Engineering design for single-room and multi-room total flooding systems
* Customized Manufacturing
In-house production of FM200 cylinders, valves, manifolds, hoses and nozzles
4.2MPa / 5.6MPa / 8.0MPa working pressure options
OEM / ODM customization and private labeling available
ISO9001 quality management with CCC certified components
* Installation & Commissioning Support
On-site installation guidance or complete installation service
System commissioning, pressure testing and functional verification
Remote technical support for overseas FM200 projects
* Technical Training (Online & On-site)
Online technical training for distributors and contractors
On-site training for large-scale fire suppression projects
Operation, maintenance and troubleshooting guidance
Complete technical documents, wiring diagrams and manuals
Get a Customized FM200 Fire Suppression Solution
Whether you need protection for a single room or a complex multi-room facility, our engineering team can provide a customized FM200 fire suppression system based on your site conditions and local standards.
📩 Contact us today to receive system drawings, technical support and a detailed quotation.