Self-Activated HFC-227ea Automatic Fire System

Self-Activated HFC-227ea Automatic Fire System

1 Products Description PRI-SAFETY Self-Activated system is specially designed used for electrical engineering rooms, electrical Panels , a small area where is not suitable with automatic fire extinguishing system by water, by powder and foaming solution. Fire extinguishing agent is contained in...
Send Inquiry
Chat Now
Description
Technical Parameters

SEO

1
Products Description

 

PRI-SAFETY Self-Activated system

is specially designed used for electrical engineering rooms, electrical Panels , a small area where is not suitable with automatic fire extinguishing system by water, by powder and foaming solution. Fire extinguishing agent is contained in gas cylinder in the form of liquefied gas and compressed with nitrogen to pressure 25 bar.

 

2
Products Features
 
 

Key Features:


Rapid Activation: Detects and suppresses fires quickly to minimize damage.


No Residue: The clean agent leaves no residue, making it safe for sensitive electronics and equipment.


Environmentally Friendly: HFC-227ea has a lower environmental impact compared to other agents like Halon, which it often replaces.
Versatile Applications: Suitable for a variety of settings, including data centers, archives, museums, and other areas with sensitive materials.

312

 

01

Clean Agent (HFC-227ea ) fire extinguishing system

02

Automatic activation by temperature
(68 ℃), NO need Smoke/Heat Detectors, No Need Electri Power for activation

03

Gas tank working pressure 25 bar

04

Easy Installation and Manetaince

 

05

Easy Installation and Manetaince

 

06

Discharge time<=10s

07

Connected cylinders activate
simultaneously on discharge gas

08

Multiple Tanks Combined together, Once one tank activated , will cause others tank activated immediately

 

3
Products Specifications

1

 

Capacity and Filling Weight
Tank Volume Code Number HFC-227ea
Filling Weight
Working
Pressure
Activated
Temperature
Discharge
Time
8L HFC-SA08/2.5-PRI 4kg~8kg 25BAR 68℃ ≤10s
12L HFC-SA12/2.5-PRI 6kg~12kg 25BAR 68℃ ≤10s
15L HFC-SA15/2.5-PRI 10kg~15kg 25BAR 68℃ ≤10s
16L HFC-SA16/2.5-PRI 10kg~16kg 25BAR 68℃ ≤10s
25L HFC-SA25/2.5-PRI 16kg~25kg 25BAR 68℃ ≤10s
 

 

 

4
Working Principle

 

Gas cylinder head valve uses fast-response glass bulb-type trigger with 68'℃ impact temperature. The thermo-sensor glass is attached with a valve structure that provides 360-degree impact protection.The system can use l stand-alone bottle for a zone or allow connection of up to 5 cylinders when equipping area with large volume.

When using gas cylinders connected together, when any cylinder in the cylinder assembly is activated by inductor the thermostat, the gas cylinders connected to the tank assembly will be stimulated simultaneously by pressure through the DN6 copper pipe, ensure that the amount of extinguishant in all cylinders is discharged within 10 seconds according to regulations. The 180 degree gas discharge nozzle, with a 5m protection distance attached to the tank head valve, will discharge extinguishant when the tank gas is activated.

 

1725352088610

 

5
How To Installation

 

Installation Guide

 

 
1725349934169

Installation Method 1:


H<=4.5m Fix on the wall,
Distance to Roof 100~400mm.

1725350706152

Installation Method 2:

H>4.5m Fix on the wall,
2 layer installation.

1725350747071

Installation Method 3:

Lorem ipsum dolor sit amet,consectetur adipisicing elit. Delectus,natus numquam unde qui pariatur porro necessitatibus harum libero commodi rem veritatis in nisi vero odit tenetur esse quidem inventore ex. Sunt nam mollitia,accusantium voluptates

23
16
6
Product Application

The PRI-SAFETY Self-Activated HFC-227ea Automatic Fire Suppression System

is designed for environments where traditional fire suppression methods, such as water, powder, or foam, are unsuitable due to the risk of damaging sensitive equipment or causing operational disruption. Given its clean agent properties and automatic activation, this system is particularly suited for the following applications:

 

1. Electrical Engineering Rooms
Application: Protects electrical engineering rooms that house critical electrical infrastructure. These rooms often contain sensitive equipment and high-voltage components, making traditional suppression methods potentially hazardous.

 

2. Electrical Panels and Cabinets
Application: Ideal for protecting electrical panels, switchgear, and control cabinets where fires can start due to short circuits, overheating, or electrical faults.

 

3. Server Rooms and Data Centers
Application: Protects server rooms, data centers, and communication hubs where sensitive electronic equipment requires a clean, residue-free fire suppression solution.

 

4. Telecommunication Facilities
Application: Suitable for use in telecom facilities where equipment is highly sensitive and requires protection from both fire and the damaging effects of water or other suppression agents.

 

5. Control Rooms
Application: Used in control rooms that monitor industrial processes, power plants, or critical infrastructure, where fire can lead to significant operational hazards.

 
 
 
12
 
612x612
 
0-612x612
 

6. Medical Facilities (e.g., MRI Rooms)
Application: Appropriate for protecting areas with sensitive medical equipment, such as MRI machines or other imaging devices, where water or powder could cause irreparable damage.

 

7. Museums, Archives, and Libraries
Application: Suitable for protecting valuable collections, rare documents, and artifacts where traditional fire suppression methods could cause irreversible damage.

 

8. Transportation (e.g., Marine Vessels)
Application: Used in confined spaces on marine vessels, such as engine rooms or control rooms, where space is limited and rapid fire suppression is critical.

 

9. Energy Sector (e.g., Transformer Rooms)
Application: Protects transformer rooms and substations where fires can result from electrical faults, posing a significant risk to energy supply.

 

10. Small, Enclosed Areas
Application: Any small, enclosed space where the use of water, powder, or foam-based systems is impractical or potentially damaging.

Summary


The PRI-SAFETY Self-Activated HFC-227ea Automatic Fire Suppression System is particularly well-suited for applications where clean, effective, and rapid fire suppression is required, and where traditional methods might cause damage or be ineffective. Its versatility makes it ideal for a wide range of environments, particularly those involving sensitive or valuable equipment.

 

 

7
Workshop

 

QQ20240902113154

QQ20240902113203

 

Hot Tags: self-activated hfc-227ea automatic fire system, China, manufacturers, suppliers, factory, made in China