Electrical Cabinet Automatic Fire Suppression System
Production Introduction
The characteristics of electrical fire hazards are the distribution, persistence and concealment of fire hazards. Due to the wide distribution of electrical systems and long-term continuous operation, electrical lines are usually laid in concealed places (such as ceilings, cable trenches), and are not easy to be detected by the fire alarm system at the initial stage of a fire, nor are they easy to observe with the naked eye. The danger of electrical fire is also closely related to the electricity consumption. When the electricity load increases, it is easy to cause electrical fires due to overcurrent.
The casualties, property losses and social shocks caused by the fire are huge. Electrical fires mainly occur in buildings, where people are close, evacuation is difficult, and smoke is not smoothly exhausted. It is very easy to cause serious accidents of mass death and injury.
PRI-SAFETY Electrical Cabinet Automatic Fire Suppression System have been specifically designed to protect electric equipment and put out electric fires caused by leakage electric(class E fire) quickly and efficiently.
These self contained pneumatic systems require no external energy or power supply. Upon flame impingement or heat, the pressurized detection tubing will burst and activate the cylinder valve to open and release the extinguishing agent.
PRI-SAFETY Electrical Cabinet Automatic Fire Suppression System are specifically designed to extinguish fires of electric panel, battery bay, control panel, electric equipment etc. It is developed to prevent damage of equipment, records, people and other assets that are vital to a business.
Production Features
Simple, high quality and well engineered system. Easy to install.
Fast, automatic actuation.
We use gas instead of water to put out the fire without causing damage.
When a fire occurs, the system will first detect it and then feedback control the fire extinguishing system to turn on and extinguish the fire within 10 seconds.
Remaining operational during power interruptio.
There is no need for manual close fire fighting.
Specification
| Item No. | EFS-01 | EFS-02 | EFS-06 | EFS-09 | EFS-12 | EFS-25 |
| Capacity | 1L | 2L | 6L | 9L | 12L | 25L |
| Extinguishing agent | FM200 / FK-5-1-12 / FE-36 | |||||
| Working pressure | 14Bar | |||||
| Test pressure | 27Bar | |||||
| Discharge pipe | φ6mm SS304 | φ6mm SS304 | φ16mm SS304 | φ16mm SS304 | φ16mm SS304 | φ16mm SS304 |
| Certification | CE Certificated | |||||
| Activation temperature of detection tube | 140℃ or Customized temperature | |||||
Drawing

Packing
Certification

Installation Example