Hangzhou PRI-SAFETY Fire Technology Co., Ltd. is known as one of the most professional manufacturers and suppliers of various safety products in China. If the 4.2mpa 150l 180l fk-5-1-12 total flooding gas fire suppression system meets your requirement, welcome to buy quality equipment made in China here from our factory. Our factory will offer you one stop service and one year warranty.
Products Description
FK-5-1-12, is a clean gaseous fire suppression agent commonly used in total flooding fire protection systems. The FK-5-1-12 Fire system is designed to extinguish fires by rapidly reducing the oxygen concentration within a protected space, thereby suppressing the combustion process. This type of fire suppression system is typically employed in areas where water-based systems might be ineffective or where the use of water could cause damage to sensitive equipment or valuable assets.


Products Specifications
| No. | Specificaitons | Technical Parameter | |
| 1 | Filling Pressure | 4.2Mpa | 5.6Mpa |
| 2 | Spray Time | 10S | |
| 3 | Cylinder Material | Stainless Steel SUS304 | |
| 4 | Cylinder Head Size | G1" / G2" | |
| 5 | Filling density | ≤950kg/m3 | ≤1080kg/m3 |
| 6 | Max working pressure | 5.3Mpa | 8.0Mpa |
| 7 | Cylinder Capacity | 70L, 90L, 120L, 150L, 180L, 250L, 345L | |
| 8 | Condition of reserving room for container | Temperature: -10~50ºC, Relative humidity: ≤97% |
|
| 9 | Nitrogen Pressure of Driving Device | 6.0±1.0Mpa(20ºC) | |
| 10 | Valve Material | Stainless Steel SUS304 | |
| 11 | Power | DC24V/1.6A | |
| 12 | Scale of Protective region for one zone | Area:max single-zone is 800m² volume:max single-zone is 3600 | |
Key Features
Clean Agent:
FK-5-1-12 is a clean gaseous agent, meaning it leaves no residue after discharge. This is particularly important in environments with sensitive electronic equipment, data centers, museums, and other areas where the residue from traditional firefighting agents (like water or foam) could cause damage.
Rapid Suppression:
FK-5-1-12 is designed to rapidly suppress fires by reducing the oxygen concentration in the protected space. This helps to control and extinguish the fire quickly, minimizing damage to property and reducing downtime.
Effective on Class A, B, and C Fires: FK-5-1-12 is effective on a wide range of fires, including those involving ordinary combustibles (Class A), flammable liquids (Class B), and electrical fires (Class C). It works by interrupting the combustion process without causing harm to electronic equipment.
Low Ozone Depletion Potential (ODP):
FK-5-1-12 has a low ODP, meaning it has a minimal impact on the ozone layer compared to some other halogenated fire suppression agents.
Short Atmospheric Lifetime:
FK-5-1-12 has a relatively short atmospheric lifetime, which contributes to its environmental acceptability. It has a Global Warming Potential (GWP) that is much lower than certain other chemical fire suppression agents.
Safe for Occupied Spaces:
FK-5-1-12 is considered safe for use in occupied spaces when applied in accordance with design and safety standards. It does not produce toxic by-products in the concentrations used for fire suppression.
Colorless and Odorless:
FK-5-1-12 is colorless and odorless, making it imperceptible to humans during discharge. This is beneficial in situations where occupants need to evacuate or emergency responders need to work without hindrance.
Precision Delivery:
The system is designed for precision delivery of the agent through a network of pipes and strategically placed nozzles. This ensures even distribution and effective coverage of the protected area.
Compatibility with Electronics:
FK-5-1-12 is non-conductive and safe for use in areas with sensitive electronic equipment. It can be an ideal choice for protecting server rooms, data centers, control rooms, and other spaces with valuable electronic assets.
Compliance with Standards:
FK-5-1-12 systems are designed and installed in compliance with industry standards and regulations. This includes adherence to guidelines provided by organizations like the National Fire Protection Association (NFPA) and local authorities.

Activation Methods:
Solenoid Head Activation Model:

A solenoid valve-activated FK-5-1-12 fire system is a type of fire suppression system that uses a solenoid valve as a key component in the activation process. The solenoid valve is an electromechanical device that controls the flow of the FK-5-1-12 fire suppression agent from the storage container to the distribution pipes and nozzles in the protected space.
Solenoid Valve: The solenoid valve is an electrically operated valve that controls the release of the FK-5-1-12 agent. It is typically located on the piping that connects the storage container or cylinders to the distribution network. When an alarm signal is received or manual activation is initiated, the solenoid valve opens to allow the pressurized FK-5-1-12 to flow into the distribution system.

Pilot Bottle Activation Model:

A pilot bottle-activated FK-5-1-12 fire system is a type of fire suppression system that relies on a pilot cylinder or bottle to initiate the release of the FK-5-1-12 extinguishing agent. This system is commonly used in applications where a fast and precise response is required for fire protection. The pilot bottle serves as a smaller, independent container of the extinguishing agent that is connected to the main storage container.
Here's how a pilot bottle-activated FK-5-1-12fire system typically works:
Pilot Bottle: The pilot bottle contains a smaller quantity of FK-5-1-12 and is pressurized. It is connected to a network of pipes that are also connected to the main storage container.
Pilot Line: A pilot valve is associated with the pilot bottle. This valve is designed to open when a specific condition is met, such as an increase in temperature or the activation of a smoke or heat detector. The pilot valve is usually a heat-sensitive device that responds to the elevated temperatures associated with a fire.
Pilot Line: The pilot bottle is connected to a pilot line that runs through the protected area. This line is typically smaller than the main distribution piping and is designed to actuate the main solenoid valve when the pilot valve opens.
Main Solenoid Valve: Similar to solenoid valve-activated systems, a main solenoid valve is used to control the flow of FK-5-1-12 from the main storage container to the distribution network. When the pilot valve opens due to a fire condition, it triggers the main solenoid valve to open, releasing the FK-5-1-12 into the protected space.
Accessory Parameters
FK-5-1-12 Cylinder Specification---4.2MPa:
(Just Listed some bottle specifications for reference)

FK-5-1-12 Cylinder Specification---5.6MPa:
(Just Listed some bottle specifications for reference)



Specifications for Head Valve of FK-5-1-12 Fire System
(High Level Model)


FK-5-1-12 Nozzle for Pipework Type


Control Panel Components:
The control panel for an FK-5-1-12 total flooding system is a critical component that monitors, controls,
and coordinates the various elements of the fire suppression system.
The components are as followings:

Our Workshop


Company Profile
PRI-SAFETY factory was built in 2005, is a national high-tech enterprise focusing on the research, design and manufacture of automatic fire suppression systems and fire fighting equipment.
And the main products we produce include : Vehicle and Mechanical Equipment Automatic Fire Suppression System, Kitchen Fire System, Heptafluoropropane Gas Fire Suppression System, FM200/FK-5112 Tool Flooding System, Water Mist Fire System, Compressed Air Foam Equipment(CAFS), Fire Trace Fire system, etc
We not only produce fire system but also design them and provide various fire solution, we have a professional technical team to help us with that, and also perfect aftersale-service.
Any question, like installlation, feel free to contact us, we are always online. And we has passed ISO9001:2015 quality management system certification, and its has CE and EN
certification, UN ECE R107 certificate for vehicle safety.
Our address
A-413, MeiDu Plaza, GongShu District, Hangzhou, China.