To meet worldwide project requirements, our company offers six fully engineered fire-suppression configurations, covering all combinations of:
System Type: Pipe Network / Cabinet Type
Cylinder Material: HP345(GB/T6653) Steel / Stainless Steel
Clean Agent: FM200 / Novec 1230
All six models are available, and we provide one-stop service including project design, OEM manufacturing, onsite installation assistance, and online/offline technical training.
⭐ This product page refers to the Link 5 ➡ Cabinet Type + HP345(GB/T6653) Steel Cylinder + Novec1230 (FK-5112) Fire Agent
Products Description
Cabinet Novec 1230 Fire Suppression System
Cabinet Type total flooding systems for single-room
Compact & Independent Clean Agent Fire Protection Solution
The Cabinet Novec 1230 Fire Suppression System is a self-contained total flooding fire extinguishing system designed for small to medium enclosed spaces.
All components-including Novec 1230 cylinder, valve, control panel and discharge nozzle-are integrated into a single cabinet, allowing fast installation, minimal site work and reliable fire protection.
This system uses Novec 1230 (FK-5112) clean agent, providing rapid fire suppression with no residue, making it ideal for protecting sensitive equipment and critical assets.



What Is a Cabinet Novec 1230 Fire Suppression System
A cabinet Novec 1230 system is a standalone clean agent fire suppression system where the Novec 1230 cylinder and control components are housed inside a protective cabinet.
Unlike pipe network systems, the cabinet system discharges Novec 1230 directly into the protected room, eliminating the need for external pipe networks and reducing installation cost and time.
How the Cabinet Novec 1230 Fire Suppression System Works?
Fire Detection
Smoke and heat detectors identify fire at an early stage.
Control and Alarm
The gas fire extinguishing control panel activates audible and visual alarms and initiates the release sequence.
Agent Discharge
The solenoid or pneumatic actuator opens the cylinder valve, releasing Novec 1230 gas into the protected area.
Total Flooding Fire Suppression
Novec 1230 gas reaches extinguishing concentration within seconds, suppressing fire quickly and effectively.
Clean and Safe Protection
The system leaves no residue, causes no corrosion, and allows rapid recovery after discharge.

Main Components of Cabient Novec 1230 System
Some accessories are available in multiple models.

We also offer fire alarm fire systems together.

Products Specification
1. Novec 1230 Fire Suppression System ( Cabient Type) Specification
| Item | Specification |
| System Type | Cabient Total Flooding Novec 1230 Fire Suppression System |
| Fire Suppression Agent | Novec 1230 (FK-5112) |
| Cylinder Material | HP345(GB/T6653) Steel or 37Mn |
| Cylinder Capacity Options | 16L / 32L / 40L / 52L / 70L / 82.5L / 90L / 100L / 120L / 140L / 150L / 180L / 250L / 300L / 345L / 450L / 500L |
| Working Pressure | 4.2 MPa (standard) / 5.6 MPa / 8.0 MPa (optional) |
| Discharge Time | ≤ 10 seconds |
| Design Concentration | 7.0% – 9.0% (depending on application) |
| Operating Temperature | -10°C to +50°C |
| System Activation | Automatic / Manual / Emergency Mechanical |
| Nozzle Type | 180°or 360° |
| Protected Area | Single zone |
| System Service Life | ≥ 20 years (with proper maintenance) |
2. Advantages of Cabinet Novec 1230 Fire Suppression System
* Compact and space-saving design
* Easy installation with no piping required
* Lower installation cost compared to pipe network systems
* Fast fire suppression within seconds
* Clean agent with zero residue
* Safe for occupied spaces
* Ideal for retrofit projects
Products Project Shows
Products Applications
Idea for, but not limited to:
* Small server rooms
* Network and communication rooms
* Electrical control rooms
* UPS and battery rooms
* Archives and document storage rooms
* Laboratories and testing rooms
Packaging & Delivery
Cylinders secured with protective frames
Valves and accessories packed individually
Export-grade wooden pallet
Palletized packaging available for bulk shipments
Suitable for sea, air and land transportation
FQA
Cabinet Novec 1230 Fire Suppression System – FAQ
Q1: What is a cabinet Novec 1230 fire suppression system?
A cabinet Novec 1230 fire suppression system is a self-contained clean agent fire extinguishing system that uses Novec 1230 (FK-5-1-12) as the extinguishing agent.
The cylinder, control panel and discharge nozzle are integrated into one cabinet, providing total flooding fire protection without external piping.
Q2: What is Novec 1230 and how does it work?
Novec 1230 (FK-5-1-12) is a fluorinated ketone clean agent that suppresses fire mainly by absorbing heat from the flame.
It extinguishes fire rapidly, leaves no residue, and does not damage sensitive electronic equipment.
Q3: Is Novec 1230 environmentally friendly?
Yes. Novec 1230 is considered one of the most environmentally friendly clean agents:
Ozone Depletion Potential (ODP): 0
Global Warming Potential (GWP): < 1
Atmospheric lifetime: approximately 5 days
It is widely accepted for projects with strict environmental requirements.
Q4: What is the difference between cabinet Novec 1230 and cabinet FM200 systems?
Cabinet Novec 1230 system
Lower environmental impact
Extremely low GWP
Preferred for green buildings and high-end projects
Cabinet FM200 system
Higher GWP
Still widely used but increasingly restricted in some regions
Both systems offer clean and fast fire suppression, but Novec 1230 is more environmentally sustainable.
Q5: Where is a cabinet Novec 1230 system typically used?
Cabinet Novec 1230 systems are commonly used in:
Server rooms
Data centers (small rooms)
Electrical and control rooms
UPS and battery rooms
Archives and libraries
Laboratories and clean rooms
Q6: How fast does a cabinet Novec 1230 system extinguish fire?
The system typically discharges Novec 1230 and reaches the design concentration within 10 seconds, providing fast and effective fire suppression.
Q7: Does Novec 1230 leave residue after discharge?
No. Novec 1230 is a clean agent that leaves no residue, no moisture and no corrosive by-products, allowing rapid recovery after discharge.
Q8: Is Novec 1230 safe for people in occupied spaces?
Yes. When designed in accordance with NFPA 2001, Novec 1230 systems are safe for normally occupied areas.
The design concentration is well below the safety exposure limits for humans.
Q9: How is the Novec 1230 agent quantity calculated for a cabinet system?
The required Novec 1230 agent quantity is calculated based on:
Room volume
Design concentration
Minimum ambient temperature
We provide professional agent quantity calculation as part of our one-stop service.
Q10: What cylinder sizes are available for cabinet Novec 1230 systems?
Common cylinder capacities include:
16L / 32L / 40L / 52L / 70L / 82.5L / 90L / 100L / 120L / 140L / 150L / 180L / 250L / 300L / 345L / 450L / 500L
Custom sizes are also available upon request.
Q11: How is the cabinet Novec 1230 system installed?
Installation is simple:
The cabinet is installed inside or near the protected room
Detection devices and control wiring are connected
No external piping or complex civil work is required
This makes it ideal for retrofit projects.
Q12: Does the cabinet Novec 1230 system require room sealing?
Yes. As a total flooding system, basic room integrity is required to maintain the Novec 1230 concentration long enough to extinguish fire effectively.
We provide guidance on room sealing and enclosure integrity.
Q13: What maintenance does a cabinet Novec 1230 system require?
Routine maintenance includes:
Visual inspection of cabinet and cylinder
Pressure gauge inspection
Control panel and detector testing
Annual system inspection
Maintenance requirements are simple and cost-effective.
Q14: What certifications do your cabinet Novec 1230 systems have?
Our cabinet Novec 1230 systems are manufactured under an ISO9001 quality management system.
Key components comply with CE and EN standards, and the Novec 1230 agent is UL listed.
Q15: Do you offer OEM or customized cabinet Novec 1230 systems?
Yes. We support OEM / ODM customization, including:
Cabinet size and color
Private labeling
Project-specific configurations
Q16: What is the production and delivery time?
Standard production lead time is 20–25 days, depending on order quantity and configuration.
Customized projects may require additional time.
Q17: How long is the service life of a cabinet Novec 1230 system?
With proper installation and maintenance, a cabinet Novec 1230 fire suppression system typically has a service life of 15–20 years.
Q18: How do I choose the right cabinet Novec 1230 system?
Simply provide:
Room dimensions
Application type
Local standards
Our engineers will recommend a suitable cabinet Novec 1230 solution and provide technical support.
About Us
Why Choose Our Cabinet Novec 1230 System
Over 15 years of fire suppression system experience
Proven quality with international project references
Strong OEM / ODM customization capability
Reliable technical support and after-sales service
One-stop service reduces project risk and total cost
One-Stop Fire Protection Solution from Design to Training
Our Novec 1230 Fire Suppression System is a proven total flooding clean agent solution designed for fast and reliable fire protection in large and complex enclosed spaces.
We provide a complete one-stop service, covering project design, customized manufacturing, installation support and technical training, ensuring smooth delivery from concept to operation.
This system uses FK-5-1-12, a clean, residue-free and electrically non-conductive fire extinguishing agent, widely applied in data centers, electrical rooms and industrial control environments.
One-Stop Service Capability
We are not only a manufacturer, but a full-solution provider of Novec 1230 fire suppression systems.
* Project Design & Engineering
System design according to NFPA 2001, ISO, EN and local standards
Novec 1230 gas quantity calculation and room integrity analysis
Pipe network layout and nozzle distribution drawings
Engineering design for single-room and multi-room total flooding systems
* Customized Manufacturing
In-house production of Novec 1230 cylinders, valves, manifolds, hoses and nozzles
4.2MPa / 5.6MPa / 8.0MPa working pressure options
OEM / ODM customization and private labeling available
ISO9001 quality management with CCC certified components
* Installation & Commissioning Support
On-site installation guidance or complete installation service
System commissioning, pressure testing and functional verification
Remote technical support for overseas Novec 1230 projects
* Technical Training (Online & On-site)
Online technical training for distributors and contractors
On-site training for large-scale fire suppression projects
Operation, maintenance and troubleshooting guidance
Complete technical documents, wiring diagrams and manuals
Get a Customized Cabinet Novec 1230 Fire Suppression Solution
Whether you need protection for a single room or a complex multi-room facility, our engineering team can provide a customized Novec 1230 fire suppression system based on your site conditions and local standards.
📩 Contact us today to receive system drawings, technical support and a detailed quotation.