Products Description

The FK5112 /Novec1230 total flooding fire suppression system is a new-generation ultra-eco-friendly clean agent fire extinguishing equipment, with perfluorohexanone as the core agent. It features comprehensive advantages of "low toxicity, no residue, and rapid fire extinguishing", and leads the world in environmental indicators.
Adopting a total flooding design, the system can fill the protected area within 10 seconds and extinguish Class A, B, C, and electrical fires through dual mechanisms of chemical inhibition and physical cooling. The agent is non-conductive and non-corrosive to equipment, leaving no residue after fire extinguishing and requiring no cleaning. Meanwhile, its low toxicity makes it suitable for enclosed spaces with personnel working.
This system supports multi-cylinder bank combination, equipped with intelligent dual smoke and heat detection + audible and visual alarm devices, and can be customized for the volume of the protected area. It is applicable to high-end scenarios with strict requirements for environmental protection and equipment protection.
Features:
--Very swift fire suppression.
--Reach extinguishing level ≤10s.
--Safe to people. People is safe when exposed at the FK5112 discharge level.
--Low extinguishing concentration. Nearly no obscure to vision in person evacuation.
--Easy to clean. No residue left, and minimize damage to sensitive equipment.
--Environment friendly. Zero ozone depletion potential and zero global warming potential.
--Sustainable technology providing an environmentally friendly solution.
--Simple installation, with small storage space.
Working Principle
Detection & Alarm: When the dual smoke and heat detectors in the protected area are triggered, the system activates the audible-visual alarm and cuts off the non-fire-fighting power supply synchronously.
Delayed Activation: After an adjustable delay (0~30 seconds, facilitating personnel evacuation), the driving device (nitrogen gas) operates to open the cylinder valves.
Agent Discharge: The FK5112 agent is discharged in a gas-liquid mixed state through pipes and nozzles, filling the protected area in a total flooding mode.
Dual-Mode Fire Suppression: The fire is suppressed via chemical inhibition of the combustion chain reaction and physical cooling. The agent remains in the area for at least 10 minutes to prevent re-ignition.


Speficication
Whole Fire System's Specification:
comparison of product parameters
| Filling Pressure | 2.5Mpa, 4.2Mpa |
| Max Working Pressure | 4.2Mpa, 5.6Mpa |
| Capacity of FM200 Cylinder | 40L 70L 90L 120L 150L 180L 250L 345L 500L |
| Material of Cylinder | Steel or Stainless Steel |
| Filling Density | 1.13 |
- ---1. Specification of Cylinder
Steel cylinder and Stainless steel cylinder
Cylinder's Specificaiton

| Item | Capacity | Thread | Diameter | Thickness | Max working pressure |
| 1 | 40L | PZ56/2-8UN.2A | 300 | 4 | 5.6Mpa |
| 2 | 90L | PZ56/3-1/4''-8UN.2A | 350 | 4.5 | 5.6Mpa |
| 3 | 120L | PZ64X2/3-1/4''-8UN.2A | 350 | 4.5 | 5.6Mpa |
| 4 | 150L | PZ64X2/3-1/4''-8UN.2A | 400 | 5 | 5.6Mpa |
| 5 | 180L | PZ80X2/3-1/4''-8UN.2A | 400 | 5.5 | 5.6Mpa |
| 6 | 250L | PZ80X2/3-1/4''-8UN.2A | 500 | 8 | 5.6Mpa |
| 7 | 345L | PZ80X2/3-1/4''-8UN.2A | 600 | 8.3 | 5.6Mpa |
| 8 | 500L | PZ80X2/3-1/4''-8UN.2A | 600 | 10 | 5.6Mpa |
---2. Specification of Valve
Normally it has 3 model valve,
For High quality VALVE

| Code No. |
AV25/4.2-PRI AV25/5.3-PRI |
AV50/4.2-PRI AV50/5.3-PRI |
| Item | G1'' | G2'' |
| Neck thread | 2-8UN.2A | 3 1/4-8UN.2A |
| Actuator thread | G1'' | G1'' |
| High pressure flexible thread | G1'' | G2'' |
| Pressure gauge thread | 1/8'' NPT | 1/8'' NPT |
| Working pressure | 6.7Mpa | 6.7Mpa |
| Test pressure | 10.05Mpa | 10.05Mpa |
| Applicable cylinder | <=70L | 90L 120L 150L 180L |
For Normal Quality Valve

| Item | DN32 | DN40 | DN50 |
| Code NO. |
V32/4.2-PRI V32/5.3-PRI |
V40/4.2-PRI V40/5.3-PRI |
V50/4.2-PRI V50/5.3-PRI |
| Neck Thread | PZ56 | M64X2 | M80X2 |
| Actuator Thread | M18X1.5 | M18X1.5 | M18X1.5 |
| Diptube Thread | RC 1-1/4'' | RC 1-1/2'' | RC 2'' |
| High Pressure flexible thread | M48X2 | M56X2 | M68X2 |
| Pressure gauge thread | M10x1 | M10x1 | M10x1 |
| Working Pressure | 4.2Mpa/5.3Mpa | 4.2Mpa/5.3Mpa | 4.2Mpa/5.3Mpa |
| Applicable cylinder | <=100L | 120L 150L | 180L 250L |
---3.Nozzles:
for nOZZLE

| Item | DN25 | DN32 | DN40 | DN50 |
| Code No. | N25-PRI | N32-PRI | N40-PRI | N50-PRI |
| Thread | RC 1'' | RC 1-1/4'' | RC 1-1/2'' | RC 2'' |
| Material | Brass | |||
---4. High Pressure Pipe, Safety valve for Manifold Pipe, Liquid Check Valve, Gas Check Valve, Pressure Switch, Pressure Gauge, etc.

--- Control Panel and Fire Alarm System
For PRI-SAFETY FM200 Total Flooding Fire System, the Control Panel And Fire Alarm System contain addressable control panel, smoke detector, heat detector, manual/auto switch, emergency start/abort button, discharge indicator light, I/O Module, Alarm(Siren/Light).

Production

Packing

Application

Company Profile

We are always at your service when you need
PRI-SAFETY FIRE TECHNOLOGY is stablished in 2005, is focused on Automatic Fire Suppression Systems and Fire Equipment R&D, Design and Manufacture.
The Main Products are On/Off Road Vehicles & Machines Automatic Fire Suppression system, HFC-227ea & FK-5112 Clean gas Fire Suppression systems, CAFS(Mobile Compressed Air Foam System), Water Mist Fire System, Foam Mist Fire System, Co2 Fire System, etc.
The Products and Fire Systems are used in Mining Industry, Forest Industry, Agriculture, Petrochemical, Transportation, Electricity Power, Industry, Construction and other fields.
PRI-SAFETY Has Professional Technology Team, Have Ability Supply Design, Solution, and Customization, For Special Project Requirement, and Technology Training & Instruction After Sales.
PRI-SAFETY Has the Certificates, ISO9001:2015, TUV CE0036, ECE R107, CCC, and So On. The Products Meet the International Standard of EN, NFPA, CNAS, ECE, etc.