China CCC Certificated FM200 Total Flooding Fire System, FM200 Gas Clean Agent Total Flooding Fire System When the control mode selection key on the automatic fire alarm and fire extinguishing controller is set to the "auto" position, the fire extinguishing system is under automatic...
Send Inquiry
Chat Now
Description
Technical Parameters

China CCC Certificated FM200 Total Flooding Fire System, FM200 Gas Clean Agent Total Flooding Fire System
When the control mode selection key on the automatic fire alarm and fire extinguishing controller is set to the "auto" position, the fire extinguishing system is under automatic control. When a fire occurs in the protection area, the temperature and smoke detectors will send out a fire signal through the automatic fire alarm and extinguishing control After the logic analysis of the device, it sends out a combined sound and light alarm signal, and sends out a linkage command at the same time to close the linkage device. After a delay, a fire extinguishing command is issued, the starting valve is opened to release the starting gas, and the starting gas is opened through the control gas pipeline valves and container valves release the fire extinguishing agent and implement fire extinguishing.

Advantages: China CCC Certificated FM200 Total Flooding Fire System,FM200 Gas Clean Agent Total Flooding Fire System

Very swift fire suppression. Reach extinguishing level ≤10s. Safe to people. People is safe when exposed at the FM200 gas discharge level. Low extinguishing concentration. Nearly no obscure to vision in person evacuation. Easy to clean. No residue left, and minimize damage to sensitive equipment. Environment friendly. Zero ozone depletion potential and zero global warming potential. Simple installation, with small storage space.
Specification
No.
Specification
Technical Parameter
1
Filling pressure
4.2Mpa
5.6Mpa
2
Scale of Protective region for one zone
Area:max single-zone is 800m² volume:max single-zone is 3600m³
3
Spraying time
10s
4
Filling density
≤950kg/m3
≤1080kg/m3
5
Power
DC24V/1.6A
6
Nitrogen Pressure of Driving Device
6.0±1.0Mpa(20℃)
7
Condition of reserving room for container
temperature: -10~50℃, relative humidity: ≤97%
8
Max working pressure
5.3Mpa
8.0Mpa
9
Min working pressure
4.2Mpa
4.6Mpa
10
Capacity
90L, 120L, 150L, 180L
Production Process
Working Diagram
Packing & Delivery
China CCC Certificated FM200 Total Flooding Fire System, FM200 Gas Clean Agent Total Flooding Fire System
Application
Application : China CCC Certificated FM200 Total Flooding Fire System, FM200 Gas Clean Agent Total Flooding Fire System
Bank vaults | Libraries | Rare book stores | Electronic data processing | Telephone exchanges | Studios | Communication centers/room | Transformer and switch-rooms | Control rooms | Test laboratories | Flammable liquid storage | Power distribution rooms | Generator rooms | Chemical combustibles warehouses | Treasures warehouses | Archives | Libraries | Offshore oil production platforms | Underground projects | Electronic computer rooms
We are known as one of the most professional manufacturers and suppliers of various safety products in China. If the fm200 gas clean agent total flooding fire system meets your requirement, welcome to the quality equipment made in China. Our factory will offer you one stop service and one year warranty.

Hot Tags: fm200 gas clean agent total flooding fire system, China, manufacturers, suppliers, factory, made in China