Products Description


FM-200 HFC-227ea is an odorless, colorless, liquefied compressed gas. It is stored as a liquid and dispensed into the hazard as a colorless, electrically non-conductive vapor that is clear and does not obscure vision. It leaves no residue and has acceptable toxicity for use in occupied spaces at design concentration. FM-200 HFC-227ea extinguishes a fire by a combination of chemical and physical mechanisms.
FM-200 HFC-227ea provides excellent fire protection in a wide range of applications from sensitive electrical equipment to industrial applications using flammable liquids. FM-200 HFC-227ea agent is used in total flooding fire suppression systems.
FM-200 HFC-227ea does not work by displacing oxygen and is safe for use in occupied spaces without fear of oxygen deprivation.
HFC-227ea FM200 Gas Total Flood Extinguishing System FM200/HFC-227EA Clean Gas Fire Suppression System for Sensitive Environments


More Choose


Products Component
Components of FM-200 HFC-227ea Total Flooding Fire Suppression Systems
1. Storage cylinder: Cylinder, container valve (with pilot valve, pressure indicator), dip tube, etc.
2. High pressure hose: Connect cylinder valve and liquid check valve .
3. Discharge Nozzle: Fitted at the end of pipe network to discharge fire suppressing agent.
4. Control System: Control panel, smoke and heat detector, fire alarm, discharge indicator light, etc.



Products Advantage
FM200/HFC-227EA Clean Gas Fire Suppression System Advantage:
* Very swift fire suppression. Reach extinguishing level ≤10s.
* Safe to people. People is safe when exposed at the FM-200 HFC-227ea gas discharge level.
* Low extinguishing concentration. Nearly no obscure to vision in person evacuation.
* Easy to clean. No residue left, and minimize damage to sensitive equipment.
* Environment friendly. Zero ozone depletion potential and zero global warming potential.
* Simple installation, with small storage space.

Products Parameters
4. FM200/HFC-227EA Clean Gas Fire Suppression System Parameters
| Item | Model | Volume x Qty |
Capacity (FM-200 HFC-227ea) |
Working Pressure (20ºC) | Max Working Pressure (50ºC) | Activate voltage/ current | Operating Temperature Range |
| 1 | GMQ4.2/90N-PRI | 90X1 | ≤100.8kg | 4.2Mpa | 5.6Mpa | DC24 V/1.2A | 0ºC-50ºC |
| 2 | GMQ4.2/120N-PRI | 120X1 | ≤134.4kg | 4.2Mpa | 5.6Mpa | DC24 V/1.2A | 0ºC-50ºC |
| 3 | GMQ4.2/150N-PRI | 150X1 | ≤168kg | 4.2Mpa | 5.6Mpa | DC24 V/1.2A | 0ºC-50ºC |
| 4 | GMQ4.2/180N-PRI | 180X1 | ≤201.6kg | 4.2Mpa | 5.6Mpa | DC24 V/1.2A | 0ºC-50ºC |
|
FM200 Cylinder Specification---4.2MPa/5.6MPa |
|||
|
No. |
Specification |
Technical Parameter |
|
|
1 |
Filling pressure |
4.2Mpa |
5.6Mpa |
|
2 |
Scale of Protective region for one zone |
Area:max single-zone is 800m² volume:max single-zone is 3600m³ |
|
|
3 |
Spraying time |
10s |
|
|
4 |
Filling density |
≤950kg/m3 |
≤1080kg/m3 |
|
5 |
Power |
DC24V/1.6A |
|
|
6 |
Nitrogen Pressure of Driving Device |
6.0±1.0Mpa(20ºC) |
|
|
7 |
Condition of reserving room for container |
temperature: -10~50ºC, relative humidity: ≤97% |
|
|
8 |
Max working pressure |
5.6Mpa |
8.0Mpa |
|
9 |
Min working pressure |
4.2Mpa |
5.6Mpa |
|
10 |
Capacity |
16/32/40/70/82.5/90/100/120/140/150/250/345/350/450/500 L |
|



Products Working Principle
M200/HFC-227EA Clean Gas Fire Suppression System Working Principle:
FM-200 HFC-227ea fire system devices are generally used in conjunction with fire detectors, fire alarm fire extinguishing controllers, emergency start/stop buttons, sound and light alarms, deflation indicators and other fire fighting equipment. When a fire occurs in the protection area, the temperature and smoke detectors will send out a fire signal. After the logic analysis of the automatic fire alarm and extinguishing controller, it will send out a sound and light composite alarm signal, and at the same time send out a linkage command to turn off the linkage equipment. After a delay time, a fire extinguishing command is issued, the solenoid valve driver is opened, the container valve is opened, the fire extinguishing agent is released, and the fire is extinguished; if the duty officer discovers a fire, he can press the emergency start button outside the protective area door to implement the fire extinguishing operation ; There is also a manual button on the solenoid valve driver, and mechanical emergency manual operation can also be used to extinguish fire in an emergency.


We also have Cabinet Type FK-5-1-12 / HFC-227ea total Flooding Fire System, FK-5-1-12/ HFC-227ea fire extinguishing system Cabinet Type FK-5-1-12/ HFC-227ea Fire Extinguisher



Products Application
The FM200 Fire system is widely used in various scenarios, including but not limited to
• Bank vaults
• Libraries
• Book stores
• Electronic data processing
• Telephone exchanges
• Communication centers • Transformer and switch room
• Control rooms
• Test laboratories
• Flammable liquid storage

Products Description